Chat with us, powered by LiveChat Skip to content

Ceramic Band Heater Configurations

Home > Products > Ceramic Band Heaters > Configurations

Thermal Corporation ceramic band heater configurations page banner

Have any questions?

Contact customer service by phone at (800) 633-2962, by email at sales@thermalcorp.com, or by using the quick chat feature located at the bottom right of the page.

Please see our accessories page to find high temperature wire, temperature controllers, ring terminals and related supplies.

Ready to Order? Click here to request a quote by selecting Ceramic Band Heater from the Select a Product drop-down!

For any Ceramic Band Heaters without clamping tabs, the following number of closures are used:

WidthNumber of Closures
1″ – 3″1
3.5″ – 5″2
5.5″ – 8″3
8.5″ – 12″4
12.5″ – 16″5

Please call customer service if you have special requirements for your heater at (800) 633-2962.
Three phase and dual voltage is also available.

Ceramic Band Heater Standard Configurations List

Below is a list of our Ceramic Band Heater configurations with a description, base price, and a drawing or diagram of each standard configuration.

Configuration & DescriptionConfiguration Diagram
Configuration 602

Ceramic Band

  • One-piece Heater

  • Post Terminals-180° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 602
Configuration 603
Ceramic Band

  • Two-piece Heater

  • Post Terminals-90° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 603
Configuration 604
Ceramic Band

  • One-piece Heater

  • Post Terminals-180° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 604
Configuration 605
Ceramic Band

  • Two-piece Heater

  • Post Terminals-90° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 605
Configuration 606
Ceramic Band

  • One-piece Heater

  • Post Terminals-180° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 606
Configuration 607
Ceramic Band

  • Two-piece Heater

  • Post Terminals-90° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 607
Configuration 614
Ceramic Band

  • One-piece Heater

  • Stainless Steel Hose-180° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 614
Configuration 615
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Hose-90° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 615
Configuration 616
Ceramic Band

  • One-piece Heater

  • Stainless Steel Braid-180° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 616
Configuration 617
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Braid-90° from gap

  • Latch and Trunnion

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 617
Configuration 618
Ceramic Band

  • One-piece Heater

  • Stainless Steel Braid-180° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 618
Configuration 619
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Braid-90° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 619
Configuration 620
Ceramic Band

  • One-piece Heater

  • Stainless Steel Hose-180° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 620
Configuration 621
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Hose-90° from gap

  • Clamping Tabs

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 621
Configuration 622
Ceramic Band

  • One-piece Heater

  • Stainless Steel Braid-180° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 622
Configuration 623
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Braid-90° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 623
Configuration 624
Ceramic Band

  • One-piece Heater

  • Stainless Steel Hose-180° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

diagram of Thermal Corporation ceramic knuckle band heater configuration 624
Configuration 625
Ceramic Band

  • Two-piece Heater

  • Stainless Steel Hose-90° from gap

  • Barrel Nuts

  • Option of Standard Insulation, Heat Saver Insulation, or Vented

 
diagram of Thermal Corporation ceramic knuckle band heater configuration 625

*Discounts May Apply. Call for Discounts Based on Order Quantity.

Written by Jennifer Taylor & Shelby Reece
Date Published: 01.17.2014
Last Updated: 03.11.2020